Xycd60 Manual -
The relay opens to protect the battery when the voltage falls to or below the Lower Limit (dn) Visual Aid: The "OUT" symbol will flash during the discharge process. Key Setup & Navigation The interface consists of an LCD screen and four buttons: UP, DOWN, SET, Short Press SET View currently set parameters (UP, dn, OP). Long Press SET Enter the parameter setting interface. Short Press UP
The XY-CD60 acts as a programmable voltage-controlled switch. It does not provide power itself; rather, it controls an onboard relay to connect or disconnect a power source (for charging) or a load (for discharging) based on voltage thresholds you define. Voltage Range: DC 6V–60V. xycd60 manual